Yale Adapts Tumor Detectors Across PET Tracers Without a Single Labeled Scan

A Yale team teaches an FDG PET/CT lesion detector to work on PSMA scans without any target labels, gaining 39 AP points by modeling label shift.

Pro

  • Yale team adapts a 3D FDG PET/CT lesion detector to PSMA scans with zero target labels via self-training.
  • Key insight: cross-tracer transfer suffers label shift, not just appearance shift, in lesion size and count.
  • Method updates RetinaNet anchor shapes with EMA based on target pseudo-label k-means each round.
  • Pseudo-labels are selected via per-subject budget and per-size-bin quotas from an online target histogram.
  • On AutoPET 2024: AP@0.1 jumps from 0.225 (source-only) to 0.613, versus 0.729 fully supervised upper bound.
  • Full paper: arXiv 2603.13666; no code release announced.

Training a tumor detector on one PET tracer and expecting it to work on another is a losing bet. Radiotracers like FDG and PSMA light up different biology, and the lesions themselves come in different sizes and counts per patient. A new paper from Yale's Biomedical Imaging Institute shows that if you explicitly model that mismatch, you can adapt a 3D lesion detector across tracers without a single labeled target scan, and recover most of the accuracy of a fully supervised model.

The work, Unsupervised Adaptation from FDG to PSMA PET/CT for 3D Lesion Detection under Label Shift, tackles a problem that quietly breaks a lot of medical AI in production: the source and target datasets do not just look different, they contain different things.

Why cross-tracer transfer breaks

FDG highlights glucose-avid tumors but also produces high physiological uptake in the brain and myocardium, while PSMA targets prostate cancer metastases with intense uptake in salivary glands and kidneys. That is the appearance shift most domain adaptation work already handles. The subtler problem is what the authors call label shift: the prevalence and size distribution of lesions can vary between cohorts of patients imaged with these different tracers.

In their data, each PSMA subject contains more small lesions on average, whereas FDG has slightly more very large lesions of at least 150 cc. A detector trained on FDG learns anchor boxes and confidence calibration tuned for bigger, sparser targets, so on PSMA it misses small metastases and merges nearby ones.

FDG vs PSMA scan comparison and per-subject lesion size histogram

The setup

The backbone is M3DRetinaNet, a one-stage object detector with focal loss to address sparse objects and multi-scale pyramid features for diverse object sizes. The authors skip adversarial feature alignment because each pyramid feature level has at least 1,000 anchor box proposals, making it inefficient to configure a discriminator at each level. Instead they use self-training: pretrain on labeled FDG, run inference on unlabeled PSMA, keep the good predictions as pseudo-labels, and alternate supervised updates on both.

The trick is what counts as a good pseudo-label.

Two mechanisms that fix the label shift

Adaptive anchor shapes. RetinaNet's initial anchor sizes come from k-means on source boxes, which is wrong for PSMA. Each round, the team re-runs k-means on the pseudo-labels from the target domain and updates anchors with an exponential moving average. This increases positive anchor coverage for small PSMA lesions and stabilizes box regression.

Size bin-wise quotas for pseudo-label selection. A naive fixed confidence threshold or top-p selection keeps the biggest, brightest lesions, which reinforces the FDG bias. Instead, they bin lesion volumes into 10 bins and allocate a per-subject pseudo-label budget across bins according to an online estimate of the target size histogram. Two priors are maintained with EMA updates:

  • A global mean of lesions per subject, controlling how many boxes to accept per case.
  • A normalized volume histogram over 10 cc bins, controlling which sizes to retain.

The budget scales up over training: the selection factor increases linearly from 0.1 to 0.8 over 200 rounds. That gentle ramp prevents early false positives from poisoning later rounds.

Numbers on AutoPET 2024

The evaluation uses the AutoPET 2024 challenge data: 501 labeled FDG PET/CT studies as the source domain and 369 18F-PSMA studies as the target domain, split into 258 unlabeled training, 37 validation, and 74 test PSMA cases.

At the loose IoU threshold of 0.1, the source-only FDG model scored 0.225 AP on PSMA. Standard self-training pushed that to 0.582. Adding anchor adaptation brought it to 0.607. The full method with label-shift-aware pseudo-label selection reached 0.613. For reference, a fully supervised model fine-tuned on labeled PSMA hit 0.729, so the unsupervised approach closes most of the gap without target annotations. At the stricter IoU 0.5, the same pattern holds: 0.128 to 0.417, versus 0.518 supervised.

FROC curves comparing no adaptation, self-training, and self-training with label shift correction

The FROC curves tell the practical story: for any tolerable false-positive-per-scan rate, the label-shift-corrected detector catches more true lesions. Without label-shift modeling, self-training tends to predict relatively larger and fewer lesions, following the label distribution in the FDG dataset.

What it is good for, and what it is not

This is a recipe for teams that already have a strong detector on one tracer and want to extend to another without launching a fresh annotation campaign. It is drop-in over any anchor-based 3D detector because the framework requires only model outputs on the target set, and it sidesteps the instability of adversarial UDA on volumetric data.

The limitations are real. The authors flag reliance on accurate binning, which can under-represent highly clustered lesions, and the one-class setting, which simplifies label shift to size and count. Multi-class detection or diseases where lesions cluster tightly in space will need a richer prior. There is also no public code release accompanying the paper, so reproducing the method means implementing the anchor EMA and bin-wise quota logic on top of an existing 3D RetinaNet like nnDetection.

The broader point

Most UDA literature treats appearance as the enemy and assumes label distributions are stable. In medical imaging that assumption is almost never true: different scanners, different tracers, different patient cohorts all shift what you are detecting, not just how it looks. Explicitly estimating target-side priors, whether size histograms, count distributions, or class frequencies, and letting them steer pseudo-label selection turns out to be a cheap and general fix. It is a useful pattern to keep in mind for any detection or segmentation transfer where the source dataset was not sampled from the same clinical reality as the target.