University of Tokyo's QDD-MM Builds Open-Source Robot Muscles Without Force Sensors

University of Tokyo researchers open-source a palm-sized muscle unit that swaps high-ratio gearboxes for quasi-direct-drive motors, cutting resistive force in half.

Pro

  • University of Tokyo open-sources QDD-MM, a muscle module using a RobStride05 QDD motor with 7.75:1 gearing.
  • Eliminates dedicated tension sensors by estimating wire force directly from motor current.
  • Delivers 133 N continuous tension and 603 mm/s winding speed at a 24 mm pulley.
  • Shows roughly 4 N resistive force versus 8 N for prior modules, and far less tension hysteresis.
  • Connectors allow parallel muscle addition and series chaining where housings become skeletal bones.
  • Validated on one-joint robots and an eight-muscle shoulder-arm prototype; project page here.

University of Tokyo researchers have released QDD-MM, an open-source tendon-drive module that combines a low-ratio actuator, winding pulley, and configurable cable routing in one reusable unit. Its quasi-direct-drive motor reduces resistance when an external force pulls the cable backward and allows motor current to estimate tendon tension, removing the dedicated load cell used in earlier modules.

Tendon-driven robots use cables to transmit force from motors to joints. Motors can sit closer to the torso while lightweight cables actuate the limbs, and opposing tendons can increase joint stiffness by pulling against each other without changing the joint angle. The engineering challenge is packaging dozens of actuators, gearboxes, sensors, and cable guides into compact, interchangeable units.

Low gearing makes tension visible

A quasi-direct-drive actuator pairs a high-torque brushless motor with a small gear reduction, typically below 10:1. The low ratio limits friction and hysteresis between the rotor and output shaft, making the actuator easier to backdrive. After calibration, torque-producing motor current also provides an estimate of output torque and cable tension. The researchers use this relationship to eliminate an inline force sensor, as described in the research paper.

A short, wide muscle unit

QDD-MM uses a RobStride05 actuator with a 7.75:1 single-stage planetary gearbox, a 24 mm winding pulley, and a detachable routing assembly that controls the Zylon cable’s exit direction. Earlier muscle modules cited by the researchers used reductions of 84:1 and 53:1 with smaller brushless motors.

Specification QDD-MM
Gear reduction 7.75:1
Pulley diameter 24 mm
Continuous output torque 1.6 Nm
Calculated continuous cable tension 133 N
No-load cable speed 603 mm/s
Module dimensions 46 × 58 × 82 mm
Labeled diagram showing the QDD-MM actuator body, winding pulley, connectors, and detachable cable-routing unit
QDD-MM separates the actuator body from the configurable cable-routing assembly.

Seven small pulleys secure the cable to the winding pulley through 3.5 turns before it reaches the knot. Using the capstan relationship with a friction coefficient of 0.3, the paper calculates that the wrap reduces the knot-side tension to about 1/731 of the input. A 133 N cable load therefore places roughly 0.18 N on the knot. The arrangement also increases the minimum bend radius from about 0.1 mm to 3 mm, reducing the sharp bend imposed by a conventional through-hole anchor.

The housing becomes part of the skeleton

The routing unit mounts on either side of the actuator body in four orientations. Depending on whether the assembly uses one or two upper pulleys, the cable can leave the module forward, backward, left, right, or upward. Four interlocking connector designs support attachment in five directions.

  • Parallel connections place several actuators on a shared structural frame.
  • Serial connections turn the actuator housings into the link between two joints.
  • Independent routing and connection directions accommodate different tendon layouts.

Bench tests show less drag and hysteresis

The researchers compared QDD-MM with a conventional sensor-driver integrated muscle module in two bench tests. During the backdrivability test, a machine pulled each cable at 5 mm/s while measuring resistance. The earlier module produced about 8 N of drag, while QDD-MM produced about 4 N. QDD-MM showed larger force fluctuations because the low-ratio drivetrain exposes more of the motor’s cogging torque.

The hysteresis test swept commanded tension from zero to a target, held it, and then reduced it while an external force gauge measured the cable load. When the command fell from 200 N to 70 N, the high-ratio module continued producing about 160 N because drivetrain friction resisted unwinding. QDD-MM produced about 80 N under the same command. The smaller gap between commanded and measured force supports current-based tension control over the tested range, although cogging and residual friction still limit accuracy.

Graphs comparing commanded and measured cable tension for QDD-MM and a high-ratio muscle module
QDD-MM follows decreasing tension commands more closely than the high-ratio comparison module.

From test joints to an eight-muscle shoulder

Three single-joint robots tested the connection options: two actuators mounted on a bone frame, three actuators joined through a parallel connector, and two housings connected in series to form the structural link. Each configuration followed a joint-angle command from 0 to −90 degrees. In the three-actuator arrangement, two agonist cables shared the load, reducing the tension carried by each cable to roughly half of the combined force.

An additional shoulder-arm prototype uses eight externally mounted QDD-MM units to coordinate scapular and upper-arm motion. The demonstration verifies a larger tendon layout, while the external motor placement leaves compact integration inside a humanoid torso for later work.

Size, cogging, and durability remain open

At 46 × 58 × 82 mm, QDD-MM has a larger cross-section than the cylindrical predecessors, whose cross-sectional dimensions were roughly 22 to 32 mm, although its depth is shorter. That shape may fit structural chains and torso-mounted arrays better than narrow limb cavities.

Current-based tension estimates retain errors from cogging torque, gearbox friction, and cable-routing hysteresis. The paper reports a 200 N command during the hysteresis sweep but specifies 133 N as the calculated continuous cable tension, so the higher test point should not be treated as a continuous rating. Long-term wear, cable life, and sustained-duty performance also remain untested.

The actuator’s torque and speed come from the commercial RobStride hardware. The research contribution lies in the cable anchor, configurable routing, structural connectors, and sensorless control approach that make the actuator reusable across tendon-driven mechanisms.

The source repository includes design files, STEP models, and a parts list. The paper has been accepted for IEEE-RAS Humanoids 2026. Together, those materials provide a starting point for building musculoskeletal prototypes without designing a custom actuator, high-ratio transmission, and inline load cell.