- Researchers modernized the classical SIENA brain atrophy pipeline by swapping in SynthStrip and SynthSeg for its weakest steps.
- Replacing BET2 skull stripping with SynthStrip drove nearly all clinical sensitivity gains in the ADNI Alzheimer's cohort.
- Correlation with CDR-SB decline jumped from r = -0.258 to r = -0.608 with the skull-stripping swap alone.
- The fully integrated pipeline cut scan-order reversal error by up to 99.1% on PPMI Parkinson's data.
- GPU-enabled variants reduced end-to-end runtime by up to 46%, mainly from replacing FAST with SynthSeg.
- Code is available at the authors' Enhanced-SIENA GitHub repo.
A group at the University of Catania has taken one of neuroimaging's most trusted longitudinal analysis pipelines and quietly rebuilt its two weakest components with deep learning, without touching the parts that clinicians actually trust. The result is a version of SIENA that correlates more strongly with cognitive decline in Alzheimer's patients, is dramatically more stable when you flip the input scan order, and runs faster on a GPU. The code is available on GitHub, and the full paper lays out exactly which substitutions matter and which don't.
The atrophy measurement problem
Percentage Brain Volume Change (PBVC) is a standard biomarker for tracking how much a brain has shrunk between two MRI scans, and it matters for evaluating whether a drug is actually slowing neurodegeneration in Alzheimer's or Parkinson's trials. SIENA estimates PBVC by analyzing the displacement of brain boundaries between two MRI scans after co-registration and tissue segmentation, and it has been the workhorse for this task for over two decades.
The catch is that SIENA is built on classical image processing. It relies on algorithms implemented in the FSL toolbox, including the Brain Extraction Tool (BET2) for skull stripping and FAST for tissue segmentation. Those algorithms use intensity heuristics and deformable surface models, and when they fail on a patient with severe atrophy or a noisy scan, the errors cascade. Small variations in the BET2 fractional intensity parameter can lead to significant differences in measured atrophy rates, and a bad brain mask poisons every downstream step.

Swap the weak links, keep the interpretable core
Rather than train a black-box end-to-end model to predict PBVC directly, the authors took a modular approach. They replaced BET2 with SynthStrip and FAST with SynthSeg, two deep learning tools trained through domain randomization. In domain randomization, fully synthetic images are generated on the fly from anatomical label maps while contrast, resolution, noise, and artifacts are stochastically varied during training, which pushes the models to generalize across scanners and acquisition protocols.
They tested three pipeline variants against the original:
- SIENA-SS: SynthStrip for skull stripping, keep FAST
- SIENA-SEG: Keep BET2, replace FAST with SynthSeg
- SIENA-SS-SEG: Both deep learning modules
One engineering wrinkle: SIENA needs a skull mask to constrain registration between scans, and SynthStrip doesn't produce one. The authors worked around this by smoothing the SynthStrip brain mask, estimating surface normals from its gradient, and casting rays outward from boundary voxels to detect the inner skull boundary using BET2's original intensity-gradient heuristic. Similarly, SynthSeg outputs anatomical structures rather than the three tissue classes SIENA expects, so the team merged its labels into CSF, gray matter, and white matter groups.
What actually moved the needle
They evaluated on longitudinal T1-weighted brain MRI data from two multi-site cohorts: ADNI for Alzheimer's and PPMI for Parkinson's, with 1,006 ADNI participants and 310 PPMI participants. Three criteria mattered: correlation with clinical decline, scan-order consistency, and runtime.
The skull-stripping swap dominated. On ADNI, SIENA-SS increased the magnitude of correlation with change in MMSE from r = -0.226 to r = -0.497, with ADAS-13 from r = -0.254 to r = -0.524, and with FAQ from r = -0.260 to r = -0.540. The largest gain was for CDR-SB, where SIENA-SS reached r = -0.608 compared to r = -0.258 for SIENA Vanilla. Replacing only the segmentation step barely moved the correlations.
The scan-order consistency results are where things get striking. A well-behaved atrophy pipeline should give you the same magnitude of volume change whether you feed it scans as (A, B) or (B, A), just with a flipped sign. The vanilla SIENA pipeline doesn't quite do this. In ADNI, SIENA-SEG achieved an 18.9% reduction in mean forward-reverse residual, while SIENA-SS yielded a substantially larger 82.4% reduction. The combined SIENA-SS-SEG pipeline provided the greatest improvement, reducing the residual by 87.8%. In PPMI, SIENA-SS achieved a 99.0% reduction and SIENA-SS-SEG achieved a similar 99.1% reduction.

Runtime and the caveats
On CPU, all four pipelines run in roughly the same 31 minutes per subject pair. The interesting number is GPU acceleration: SIENA-SEG and SIENA-SS-SEG reduced mean runtime to 1001.9 s (approximately 16.7 min) and 1166.4 s (approximately 19.4 min), respectively. Replacing FAST with the neural segmentation model is where the real speedup lives, because BET2 was already fast.
The PPMI results are more muted. The modified pipelines shifted associations toward the expected negative direction when skull stripping was replaced, but none of the differences versus baseline were significant after Bonferroni correction. The authors are upfront that they used surrogate endpoints because in-vivo ground truth for brain atrophy is essentially impossible to obtain, and they didn't compare against non-SIENA frameworks like BSI.
The broader lesson is a template for how to modernize legacy clinical tooling. Instead of asking a neural network to do the whole job and losing interpretability, identify the specific stages that break most often, drop in a modern replacement, and keep the validated analytical machinery intact. For SIENA, brain extraction was the load-bearing failure point, and fixing it fixed most of what was wrong.