Skip to main content
Back

UnConKeD Beats Supervised Eye-Scan AI Without a Single Labeled Image

A new unsupervised method learns retinal image descriptors without labels or a fixed keypoint detector, matching or beating supervised state of the art on FIRE.

Pro

Paper, Full Access
  • UnConKeD trains retinal image descriptors without labeled keypoints, using random RoI sampling and FastAP contrastive loss.
  • Descriptor is detector-agnostic: works with SIFT, Harris, FAST, ORB, CenSurE, or vessel-based detectors at inference.
  • Beats supervised ConKeD++ (0.769 vs 0.765 weighted AUC) on the FIRE benchmark using identical keypoints.
  • AV Skeleton + Canny variant hits 0.790 weighted AUC, best among deep learning methods on category A.
  • Built on ConKeD++ multi-view batch (1 original + 9 augmentations), trained on Messidor-2 with two A100 80GB GPUs.
  • Even a fully random 40k-point grid rivals detector-less transformer baseline GeoFormer, showing descriptor quality dominates.

Registering two images of the same retina, taken months or years apart, is one of those clinical tasks where deep learning has struggled to fully displace classical methods. The reason is not architecture. It is labels. Annotated pairs of fundus images are scarce, and the best neural pipelines tend to hard-code a specific detector into the descriptor, meaning you cannot swap parts without retraining. A new paper from the VARPA group at the University of A Coruña proposes UnConKeD, an unsupervised descriptor network that is agnostic to whatever keypoint detector you feed it.

The claim is unusually strong: the unsupervised training does not rely on keypoint detection, which makes the resulting descriptor network agnostic to the keypoint detector used during registration inference, and across the standard benchmark it matches or beats the supervised baseline it was built from.

Why retinal registration is stuck

Color fundus (CF) images are cheap, widespread, and useful for diagnosing eye disease and systemic conditions, but they are messy: blur, glare, motion artifacts, and morphological changes between visits all conspire against alignment. In practice, the best-performing pipelines are keypoint-based, matching landmarks like blood vessel crossovers and bifurcations. Two families dominate the deep learning side:

  • Detector-based methods like SuperRetina and ConKeD/ConKeD++, which jointly or sequentially train a detector and a descriptor. They work, but the descriptors are tied to the detector they were trained with.
  • Detector-less methods like GeoFormer (built on LoFTR), which extract dense matches with transformers. They avoid keypoints but at higher compute cost.

Both camps hit the same wall. Supervised detectors need labeled crossovers and bifurcations. Unsupervised detector-based methods, until now, could not compete on accuracy.

The trick: sample keypoints at random during training

The proposal builds directly on ConKeD++, which uses a multi-view contrastive setup with a FastAP ranking loss. In the original, a supervised detector picks vessel crossovers and bifurcations, and the descriptor is trained only on those points. UnConKeD swaps that step out: instead of relying on a supervised detector network, the descriptor network is trained using randomly sampled points, which removes any dependency on labeled data and lets it learn descriptors for arbitrary keypoints in the retina.

The rest of the recipe is deliberately similar to ConKeD++ so that comparisons are clean:

  • Each batch contains 1 original image plus 9 augmented views (rotations up to 60 degrees, translations, scaling, shear, HSV shifts, Gaussian noise).
  • 1,460 keypoints are sampled per image from the retinal region of interest, then dense descriptor maps are computed and the loss is applied only at the sampled locations.
  • Training runs for 1,000 epochs with Adam at a fixed learning rate of 1e-4, using two Nvidia A100 80GB GPUs on the Messidor-2 dataset (1,748 images).

Because the sampling is uniform over the RoI rather than tied to vessel structure, the network is forced to produce useful descriptors for the entire retinal surface, not just anatomical hotspots. The authors note the flip side: many samples land on low-interest background pixels, which slows convergence but improves robustness at inference.

Any detector you want at inference time

Once trained, the descriptor is decoupled from any specific detector. The authors stress-test it with a wide range of options and even propose new ones:

  • Classical detectors: SIFT, Harris, FAST, ORB, CenSurE.
  • Domain-specific: blood vessel crossovers and bifurcations (the ConKeD++ default).
  • Novel: run a vessel segmentation network, then use either the raw skeleton, Canny edges over the vessels, or classical detectors applied to the segmentation logits instead of the raw image.

What the numbers say

Evaluation uses the FIRE benchmark, which contains 134 fundus image pairs split into category S (high overlap), P (low overlap), and A (high overlap with disease progression, the most clinically relevant). Scoring uses the standard Registration Score AUC.

Head-to-head against its supervised parent using the same vessel crossovers and bifurcations, UnConKeD scores 0.769 weighted average versus ConKeD++ at 0.765. Small but meaningful, given that this is the setup most favorable to the supervised method. More importantly, swapping detectors barely moves the needle in the wrong direction:

Detector + UnConKeDKeypointsWeighted Avg AUC
Vessel crossovers/bifurcations1150.769
CenSurE over vessel logits5000.767
AV Skeleton (sub-sampled)1,8070.786
AV Skeleton + Canny24,6310.790
Random keypoint grid40,0000.782
ConKeD++ (supervised baseline)1150.765
GeoFormer (detector-less)dense0.784
VOTUS (classical)-0.811

Two results stand out. First, on category A, the pathological progression pairs, the vessel-Canny and sub-sampled skeleton variants top all deep learning methods. Second, a fully random 40k-point grid, with no learned or handcrafted detection at all, lands within noise of GeoFormer, hinting at how much of the heavy lifting the descriptor itself is doing.

What is actually new

The headline is unsupervised training, but the real breakthrough is decoupling. In every prior keypoint-based CF pipeline, the descriptor is trained only on the class of point the detector produces. Feed it a Harris corner instead of a bifurcation and it fails. UnConKeD produces embeddings that are usable at any pixel in the RoI, which turns detector choice into a runtime knob rather than a training commitment.

That has practical consequences. You can trade accuracy against compute by scaling detector output from 100 to 40,000 points, or pick a detector that is robust to the specific artifacts in your dataset without retraining the descriptor. Applying classical detectors to vessel segmentation logits, for example, gave CenSurE a strong 0.767 score with only 500 keypoints, which is fewer than any competing method at that accuracy level.

Caveats worth knowing

Classical VOTUS still wins overall on FIRE at 0.811, though it falters on the clinically important category A where UnConKeD leads. Random sampling during training does mean a lot of gradient updates are spent on uninformative background, and the paper does not publish training-time comparisons against ConKeD++. There is also no public code release announced in the paper. The methodology is described in enough detail to reimplement, but no repository or model weights are linked, and the reference dataset (Messidor-2) requires registration to access.

Still, for anyone working on medical image alignment where labels are the bottleneck, the takeaway is direct: you can train a competitive descriptor with nothing more than augmented views and random point sampling, and then bolt on whatever detector suits the deployment.