Skip to main content
Back

MD Anderson's ProFed Beats 11 Rivals by Denoising CT Scans Before Reconstruction

ProFed moves personalization into the sinogram space, using CT physics to separate scanner noise from patient anatomy across hospitals.

Pro

Paper, Full Access
  • ProFed personalizes federated LDCT denoising in projection space, where scanner noise and anatomy are naturally separated.
  • Anatomy-aware and protocol-aware branches modulate the decoder through a learned gating mechanism.
  • Forward, backward, and cycle projection losses enforce consistency with raw sinogram measurements.
  • Achieves 42.56 dB PSNR (CNN) and 44.83 dB (Transformer) on Mayo Clinic 2016, beating 11 baselines.
  • Improves +1.42 dB over prior physics-informed SCAN-PhysFed while keeping parameters constant with client count.
  • Uncertainty-weighted aggregation via Monte Carlo dropout balances local personalization with global collaboration.

Hospitals want to train better low-dose CT denoisers together, but they cannot share patient scans, and every scanner adds its own fingerprint of noise. A new framework called ProFed tackles both problems at once by shifting personalization in a federated learning pipeline from the reconstructed image back to the raw projection measurements. On the standard Mayo Clinic benchmark it beats eleven existing federated baselines, including the previous physics-informed state of the art.

The mess between dose and diagnosis

Low-dose CT reduces radiation exposure by decreasing tube current and sampling fewer projection views, which is good for patients but bad for images. Reconstructions come out noisy, streaky, and short on anatomical detail. Deep learning fixes this well when you can train on a large centralized dataset, but medical data lives behind hospital walls, and every institution runs different scanners with different acquisition protocols.

Federated learning is the standard workaround: hospitals train locally and share only model weights. Existing federated LDCT methods personalize in image space after reconstruction, where protocol-dependent noise and patient anatomy are already fused. Once the sinogram has been back-projected into a picture, the streaks from a low-dose scanner and the shape of a patient's liver are tangled into the same pixels, and no amount of clever image-space adaptation cleanly pulls them apart.

Going upstream to the sinogram

The key insight from the MD Anderson team is physical, not architectural. Noise in CT scans originates in the raw measurement before image reconstruction. Protocol noise and anatomy are naturally separated in the projection domain: noise appears as inconsistent measurements, while anatomical structures maintain consistent patterns across viewing angles. A sinogram is the stack of X-ray line integrals recorded at each rotation angle before the reconstruction algorithm turns them into a picture. Personalizing there gives you a chance of learning "this is what my scanner's noise looks like" separately from "this is what this patient's anatomy looks like."

ProFed architecture showing encoder, anatomy-aware and protocol-aware branches, modulation block, decoder, and federated aggregation across client hospitals

How ProFed is wired together

The framework keeps a familiar encoder-decoder backbone (they test both RED-CNN and Uformer) but wraps it in three new pieces:

  • Dual adaptation. An anatomy branch extracts patient features from the image plus a BioBERT embedding of a synthetic radiology-style description, while a protocol branch encodes the seven-dimensional scanner metadata (dose, geometry, kVp, mAs) and injects it into the decoder with a rank-8 LoRA adapter.
  • Gated modulation. A learned sigmoid gate mixes the anatomy and protocol modulation parameters channel by channel, so the network can lean on protocol cues when anatomy features look unreliable.
  • Projection consistency losses. A differentiable Radon transform and filtered back-projection let the model check its own output against the real sinogram in three ways: forward (reprojected image should match measurements), backward (image should match FBP of measurements), and cycle (round-trip should be identity).

On the server side, each client computes predictive uncertainty using Monte Carlo dropout on its validation set, and those numbers weight the aggregation. Clients more confident on their local data contribute more to the shared encoder, decoder, and protocol network, while the anatomy-aware modulation and the reliability gate stay local to each hospital.

What the numbers say

Experiments use the NIH-AAPM-Mayo Clinic 2016 dataset, with 5,936 CT scans from ten patients; eight patients were used for training and two were reserved for testing. The eight training patients are split across eight virtual clients, each with a distinct protocol configuration, and four additional unseen protocols on the held-out patients test generalization.

Across all settings ProFed achieves 42.56 dB / 98.23% (CNN), 44.83 dB / 98.61% (Transformer), and 39.17 dB / 93.33% (unseen clients). Against the strongest prior baseline, it improves by +1.42 dB (CNN), +1.18 dB (Transformer), and +0.62 dB (unseen) over SCAN-PhysFed, which itself uses physics constraints but only in image space.

The ablations sharpen the story. Running the same anatomy- and protocol-aware personalization in projection space instead of image space adds roughly 0.9 to 1.4 dB on its own. Uncertainty-weighted aggregation contributes a more modest +0.13 dB, which suggests the win is really about where you personalize, not how you average.

Scaling behavior worth noting

One practical wrinkle: SCAN-PhysFed grows its parameter count with the number of clients, ballooning to 18.8M at K=100. ProFed keeps constant O(1) scaling at 3.0M parameters regardless of federation size, and shaves 14% off communication overhead by extracting anatomy features offline once per sample rather than every epoch. For a real hospital consortium with dozens of sites, that difference matters more than a fraction of a decibel.

Where it fits and where it doesn't

ProFed is most useful when you have three things: sinogram access (not just reconstructed DICOMs), protocol metadata in the headers, and paired low-dose/normal-dose data for supervision. That last requirement is the same as every baseline in the paper, but it does rule out purely retrospective deployments where full-dose references don't exist.

The authors flag two honest limitations. Protocol adaptation depends on metadata like kVp, mAs, and scanner geometry, which is routinely available in clinical DICOM headers but not guaranteed to be complete. The anatomy branch also leans on BioBERT embeddings of image-captioned descriptions rather than a dedicated CT anatomy encoder, and the authors suggest a self-supervised encoder trained directly on CT volumes as a natural next step. The release does not include a public code repository.

Match the representation to the physics

Beyond the LDCT numbers, ProFed is a clean argument for choosing your representation to match the physics of your heterogeneity. Federated medical imaging has spent years piling personalization tricks onto image-space models (batch norm layers, adapters, hypernetworks, feature disentanglement) and hitting diminishing returns. Moving one step upstream, to where the noise actually originates, gives the same personalization machinery substantially more to work with. The same reasoning could apply to MRI k-space, PET list-mode data, or any other modality where the measurement domain is more physically interpretable than the reconstructed one.