Endo-UC Benchmark Exposes a Critical Gap in AI Colitis Grading
A multi-centre endoscopy dataset pairs Mayo and UCEIS severity scores with expert-written captions, enabling automated ulcerative colitis grading and reporting.
ProTakeaways
- Endo-UC releases 2,495 multi-centre colonoscopy images with dual MES and UCEIS severity labels plus expert captions
- Three subsets span published HyperKvasir data, high-resolution Olympus captures, and low-resolution video frames
- Each image annotated on five clinical axes: vascular pattern, bleeding, erythema, erosions/ulcers, friability
- DINOv2-Large leads classification at 71.4% top-1 accuracy, beating Swin, ViT, ConvNeXt, and ResNet50
- BLIP-Large hits 0.86 ROUGE-L for generating clinically structured endoscopic captions
- Mid-severity MES-1 and MES-2 remain the hardest classes across all tested backbones
Ulcerative colitis grading has long been stuck in a familiar bottleneck for medical AI: the models exist, but the labeled data does not. A new benchmark called Endo-UC tries to close that gap by releasing a curated, multi-centre colonoscopy dataset that carries not just severity labels but also expert-written descriptions of what the mucosa actually looks like.
Why grading colitis is harder than it sounds
Ulcerative colitis is a chronic inflammatory disease of the colon and rectum, and patients with long-standing UC have a 2 to 4-fold higher risk of developing colorectal cancer due to persistent inflammation of the colonic mucosa. Clinicians grade severity during colonoscopy using two descriptive scales: the Mayo Endoscopic Score (MES), which ranges from 0 to 3, and the Ulcerative Colitis Endoscopic Index of Severity (UCEIS), which ranges from 0 to 8. Both are subjective, and the grading depends heavily on the clinician's experience level, so differences in assessments can still affect patient diagnosis.
Prior deep learning attempts have shown promise but hit a ceiling. Existing methods generally sit below 80% classification accuracy, have not been rigorously assessed on multi-centre data, and lack language descriptions that would improve interpretability. That last point matters: a numeric score alone gives a clinician no reason to trust the model.
What is actually in the dataset
Endo-UC bundles 2,495 colonoscopy images from three sources with very different characteristics, which is the point. Subset I contains 1,197 images sourced from previously published works including HyperKvasir, re-annotated to add UCEIS scores and captions that were missing. Subset II adds 516 high-resolution images captured directly from an Olympus endoscopy processor at a clinical centre in Egypt, and Subset III contributes 782 low-resolution frames extracted from the recorded video stream at the same centre, adding variability in spatial resolution, lighting, and image clarity.

Every image was reviewed by gastroenterologists and annotated along five clinical axes:
- Vascular pattern: normal, patchy, or obliterated
- Bleeding: none, mucosal, mild luminal, or moderate/severe luminal
- Erythema: none, mild, or marked
- Erosions and ulcers: none, erosion, superficial, or deep ulcers
- Friability: none, low, moderate, or severe
These features are then combined to assign the MES and UCEIS scores, and a Python routine composes them into a standardised caption sentence for each image. That structured pipeline is what makes the captions clinically grounded rather than free-form GPT prose.
What the benchmarks show
The authors ran seven classification backbones and both sizes of BLIP for captioning, evaluating on 311 held-out low-resolution frames. Self-supervised vision transformers came out on top.
| Model | Top-1 Acc | F1 | AUC |
|---|---|---|---|
| DINOv2-Large | 0.714 | 0.659 | 0.769 |
| DINOv2 | 0.695 | 0.600 | 0.745 |
| DINOv3 | 0.688 | 0.607 | 0.747 |
| Swin Transformer | 0.672 | 0.588 | 0.734 |
| ViT | 0.662 | 0.554 | 0.729 |
| ConvNeXt | 0.662 | 0.583 | 0.736 |
| ResNet50 | 0.601 | 0.493 | 0.680 |
DINOv2-Large's lead across accuracy, F1, AUC, sensitivity, specificity, and PPV suggests that self-supervised visual representations provide better feature extraction than the other tested models. The per-class breakdown is more revealing though. MES-3 (severe colitis) is generally easy to detect with high sensitivity, but MES-1 and MES-2 (mild and moderate severity) are much harder to classify accurately due to subtle differences in mucosal texture and vascular patterns. This is the clinically meaningful failure mode: the model is best at cases a clinician would spot anyway.
For captioning, BLIP-Large outperformed BLIP-Base on every metric, reaching a cosine similarity of 0.7977, BLEU-1 of 0.8210, METEOR of 0.8435, and ROUGE-L of 0.8574. Those are strong numbers, but they partly reflect the templated nature of the captions themselves.

Why this matters beyond the leaderboard
The real contribution here is not a new architecture. It is that this is described as the first comprehensive dataset combining dual scoring metrics for classification with expert-generated captions describing mucosal appearance and clinically accepted reasoning for image captioning. That combination unlocks a few things that were awkward before:
- Training models that output both a severity score and a defensible textual justification tied to vascular pattern, bleeding, and ulceration
- Cross-institution generalisation testing, since the three subsets differ in scanner, resolution, and capture method
- Direct comparison of CNNs, ViTs, and DINO-family self-supervised encoders on the same clinical task
The paper does not indicate a public code or dataset release URL in the available text, so access likely requires contacting the authors at the University of Leeds. For teams working on gastrointestinal AI, this is one of the few resources that ties image-level severity to structured clinical descriptors rather than radiology-style free text, and the mid-severity gap it exposes is a clear target for the next round of models.