ASU's LETetCNN Resolves Alzheimer's Blood Test Gray Zone With 79.8% Accuracy
A transformer model for 3D brain meshes catches Alzheimer's amyloid buildup in the patients blood tests can't classify, without a PET scan
ProTakeaways
- Core result: LETetCNN classifies amyloid positivity in blood-test "medium-risk" patients at 79.8% accuracy vs. 67.5% for blood tests alone, potentially avoiding PET scans.
- Novel architecture: First transformer model designed for tetrahedral meshes; uses Gaussian Process landmarks to tokenize 70k-100k vertex brain meshes into 1,000 patches.
- AD classification: Achieves 91.7% accuracy on AD vs. cognitively normal, and 79.4% on the harder MCI vs. CN task -- ~5% above prior TetCNN baseline.
- Fusion approach: Combines 3D brain mesh features with pTau-217 blood biomarker via late fusion, each providing complementary signal.
- Clinical relevance: Targets the "gray zone" patients (10-40% of screened individuals) who currently require costly ($3,000+) amyloid PET scans for confirmation.
- No public code: Model not yet released; evaluated on ADNI dataset with modest medium-risk cohort (n=166), requiring external validation.
Confirming Alzheimer's disease today often means a PET scan -- a procedure that exposes patients to radioactive tracers and can cost upwards of $5,000. Blood tests for proteins like phosphorylated tau (pTau-217) have emerged as a cheaper, less invasive screening tool, achieving 92% sensitivity in distinguishing AD from other neurodegenerative disorders. But there's a catch: blood tests sort patients into three buckets -- low, medium, and high risk -- and the medium-risk group, which can represent 10% to 40% of patients, still gets sent for a PET scan because the blood test alone can't make the call.
A team from Arizona State University and Banner Alzheimer's Institute has now published a paper showing that a transformer-based model operating on 3D brain mesh data can resolve exactly that ambiguity -- classifying amyloid positivity in the medium-risk group with 79.8% accuracy, compared to 67.5% for the blood test alone.
Why MRI scans are hard to learn from
Standard MRI images are stored as 3D grids of voxels, which work fine for coarse analysis. But the brain's cortex is a thin, highly folded sheet, and voxel grids can't capture fine-grained geometric detail at arbitrary resolution. Volumetric mesh data structures, such as tetrahedral meshes, offer comprehensive insights by modeling both surface and interior aspects of substances -- think of them as a 3D triangulation of the brain's grey matter, capturing both the outer surface and the interior volume simultaneously.
The problem is that tetrahedral meshes are irregular: two brains won't have the same number of vertices or the same topology. Standard graph neural networks (GNNs) struggle here because of the over-squashing nature of message-passing neural networks, potentially aggregating unnecessary or redundant information from intermediate nodes when interacting with long-range nodes. Transformers, which use attention to directly relate any two points regardless of distance, are a natural fix -- but applying them to meshes with 70,000 to 100,000 vertices is computationally brutal.
Landmarks as the key to scalable attention
The core innovation in this work, called LETetCNN (Landmark-Enhanced TetCNN), is a tokenization strategy that makes transformer attention tractable on large, variable-size meshes. The pipeline works in four stages:
- Landmark generation: A pre-trained Gaussian Process (GP) model -- which encodes geometric features using a multi-frequency periodic diffusion kernel -- automatically places 1,000 anatomical landmarks on each brain mesh. These landmarks act as semantically meaningful anchor points, similar to how a radiologist's eye gravitates to specific sulci and gyri.
- Patch creation: Each of the ~70k-100k mesh vertices is assigned to its nearest landmark using K-nearest neighbors, creating 1,000 patches (tokens). Unlike ViT image patches, these patches have variable node counts, so the model can't just concatenate raw inputs.
- Local feature learning: Two layers of TetCNN -- a graph convolution that uses the volumetric Laplace-Beltrami Operator (LBO) instead of a standard graph Laplacian -- extract local geometric features within each patch. The LBO is a generalization of the Laplacian to curved surfaces; it captures how signals spread through the brain's geometry. Each patch is then summarized by averaging its node features into a single token embedding.
- Sparse attention: Rather than running full self-attention over all 1,000 tokens (which is O(n²)), the model builds a radius graph connecting only spatially nearby landmark tokens. Attention scores incorporate both feature similarity and relative 3D position, letting the model reason about both what a region looks like and where it sits in the brain.

Blood-based biomarkers are then fused in at the final fully-connected layer by concatenating the pTau-217 value directly with the learned mesh features -- a simple but effective late-fusion approach.
Two tasks, two datasets, consistent wins
The model was evaluated on two separate subsets of the ADNI dataset (Alzheimer's Disease Neuroimaging Initiative), the standard benchmark for AD research.
Task 1 -- Clinical AD classification: 947 samples from 906 individuals, including 313 with Alzheimer's disease, 402 with mild cognitive impairment (MCI), and 229 cognitively normal (CN). LETetCNN outperformed all baselines across every pairwise comparison:
| Task | GAT | TetCNN | LETetCNN |
|---|---|---|---|
| AD vs CN | 85.8% | 87.6% | 91.7% |
| AD vs MCI | 72.7% | 70.9% | 75.5% |
| MCI vs CN | 72.2% | 73.0% | 79.4% |
Task 2 -- Amyloid positivity in medium-risk patients: 909 data samples with matching T1-weighted brain MRI, PET scan and pTau-217 measured by PrecivityAD2. The medium-risk subset contained 70 amyloid-positive and 96 amyloid-negative individuals. Hippocampal volume yielded results close to random classification, while pTau-217 alone achieved 0.675 classification accuracy. LETetCNN alone hit 75.8%, and the performance was further enhanced after integrating pTau-217, reaching a classification accuracy of 0.798 with a balanced prediction (SEN=0.785, SPE=0.811).
The MCI vs CN result deserves special attention. Determining AD pathology in the preclinical stage remains challenging, as less significant morphological changes can be observed -- yet this is exactly when intervention matters most. The ~7 percentage point gain over TetCNN in that comparison suggests the landmark-based tokenization is genuinely capturing subtle structural signals.
What the model is actually looking at
Grad-CAM (Gradient-weighted Class Activation Mapping -- a technique that highlights which input regions most influenced a prediction) was applied to visualize where the model focuses. The highlighted areas were spreading around posterior cingulate and medial temporal lobe, with some less significant regions located in frontal lobe. This is a meaningful sanity check: medial temporal lobe has been widely reported as the first region affected by AD, and posterior cingulate was also shown to be functionally important in impairment of learning and memory.

The real unlock: filling the blood-test gap
The most practically significant result isn't the AD classification accuracy -- it's the amyloid positivity task. Recently approved anti-amyloid immunotherapies for Alzheimer's disease require evidence of amyloid-β pathology from PET or CSF before initiating treatment, and blood-based biomarkers promise to reduce the need for PET or CSF testing. The problem is that blood tests leave a substantial gray zone. Two-threshold strategies improve blood biomarker performance but require confirmatory testing by PET in a non-negligible portion of patients that fall in an intermediate range.
LETetCNN + pTau-217 offers a potential path to resolving that gray zone using only an MRI scan -- which is already routinely ordered for patients with cognitive complaints -- rather than a radioactive PET scan. The approach is complementary: blood tests triage the easy cases, and the MRI model handles the hard ones.
Limitations and what's next
The dataset sizes are modest -- 166 medium-risk samples for the amyloid task -- and external validation on independent cohorts hasn't been done yet. The preprocessing pipeline is also non-trivial: MRI images go through FreeSurfer surface reconstruction, TetGen mesh generation, and GP landmark extraction before any learning happens, which adds latency and infrastructure requirements. No code or pre-trained models have been released publicly at this time.
The broader contribution to geometric deep learning is real regardless: this is the first approach to extend transformer architectures to tetrahedral meshes, leveraging relative positional encodings and task-specific graph tokenization for efficient and geometry-aware representation learning. The technique isn't AD-specific -- any domain that uses volumetric mesh representations (cardiac modeling, orthopedic implant design, finite element simulation) could benefit from this tokenization approach.