Skip to main content
Back

Ant Group's LingSante-3.1-flash Tops Open Medical AI With 560B Parameters

Ant Group's inclusionAI drops a 560B-parameter open-weight medical mixture-of-experts model with a one-million-token context under MIT license.

Pro

Model, Full Access
  • Ant Group's inclusionAI released LingSante-3.1-flash, a 560B-parameter medical MoE with 25B active parameters under MIT license.
  • Built on Ling-3.1-flash with 1M-token context, 512 routed experts, and a hybrid KDA plus gated MLA attention stack.
  • Trained via medical-mixed pretraining, SFT, task-specific RL, and multi-teacher on-policy distillation.
  • Ranked #1 open-source on InclusionMed and #2 overall on professional behavior benchmarks behind GPT-6 Astra.
  • Day-0 SGLang and vLLM support with MTP speculative decoding; FP8 and MXFP4 builds available.
  • Explicitly a research tool, not a medical device; targets literature synthesis, agents, and clinical document analysis.

Ant Group’s InclusionAI team has released LingSante-3.1-flash, an open-weight medical reasoning model with 560 billion total parameters, 25 billion active parameters per forward pass, and an advertised one-million-token context window. The weights carry an MIT license, giving researchers and companies broad rights to use, modify, and redistribute the model.

Ant says the LingSante family will arrive in phases. The first two releases are LingSante-3.1-flash, the large text reasoning model covered here, and LingSante-3.1-air-VL, a smaller multimodal companion. The combination of permissive weights, sparse computation, and long context expands the options for medical AI research, although serving the full model requires data-center hardware.

Huge weights, sparse compute

LingSante-3.1-flash specifications
Component Specification
Base model Ling-3.1-flash
Architecture Sparse mixture of experts with hybrid linear attention
Total parameters 560 billion
Active parameters 25 billion per forward pass
Transformer layers 63 KDA layers and 9 gated MLA layers
Experts 512 routed experts plus one shared expert
Experts per token 8 routed experts
Hidden size 4,096
Maximum context 1 million tokens
Modality Text
License MIT

The 72-layer transformer stack combines kernelized or linear-attention layers, called KDA, with gated multi-head latent-attention layers, called MLA, in a 7:1 ratio. Linear attention avoids constructing a full token-to-token attention matrix at every layer, which helps control the cost of long prompts. MLA compresses key-value representations used during inference.

Sparse routing sends each token through eight of the 512 routed experts, alongside a shared expert. That design lowers the computation performed for each token. Serving still requires access to all 560 billion parameters, so the sparse architecture does not remove the model’s substantial storage and memory requirements.

The one-million-token limit is a maximum supported context rather than a practical default for every request. Prompt processing time, accelerator memory, concurrency, and retrieval quality still change as context grows. Production teams will need workload-specific tests at their intended prompt lengths.

Medical training in four stages

InclusionAI describes a four-stage training recipe that preserves general reasoning, coding, and tool-use data while adding medical knowledge and behavior:

  1. Medical-mixed pretraining and mid-training: Medical and general-domain material remain in the training mixture.
  2. Supervised fine-tuning: Clinically grounded examples teach target response formats and task behavior.
  3. Task-specific reinforcement learning: Training rewards medical reasoning, evidence search, tool use, and professional conduct.
  4. Multi-teacher on-policy distillation: Several specialist teachers generate training signals that are consolidated into one checkpoint.

The distillation stage allows separate teachers to specialize in areas such as evidence verification, search, and long-horizon workflows. LingSante-3.1-flash then absorbs those behaviors into a single model that can be served without coordinating several specialist checkpoints.

Scores shift across tests

Ant reports that LingSante-3.1-flash leads open-weight medical and health models on InclusionMed, an evaluation platform developed with researchers from 29 institutions, including Stanford University, Harvard University, and Peking Union Medical College. Because InclusionAI participates in the platform and publishes the model, the result should be read as a vendor-reported benchmark rather than a fully independent evaluation.

Reported evaluation results
Evaluation Result Context
InclusionMed overall 45.064, fifth of 23 configurations Includes proprietary and open-weight systems
InclusionMed open-weight ranking First Medical and health models only
Professional behavior Second Behind a system labeled GPT-6 Astra on the published leaderboard
MLCR-AA 23.3% Third-party test of long-context medical reasoning over held-out documents
Published benchmark table comparing LingSante-3.1-flash with other medical models
InclusionAI’s published comparison of LingSante-3.1-flash with other evaluated models.

Scores from InclusionMed and MLCR-AA cannot be compared directly because the suites use different datasets, rubrics, and task distributions. The gap does show why developers need evaluations built from their own documents, specialties, tools, and failure costs before selecting a model.

Community tests on BenchClub have also examined calibration, which measures whether stated confidence matches the available evidence. LingSante-3.1-flash labels answers with high, moderate, or low certainty. In one pregnancy-hypertension question, it assigned high certainty to the primary composite outcome and moderate certainty to rarer outcomes. In a statin question, it rated high-grade evidence as moderate and lost points. These examples reveal useful behavior, although they do not establish calibration across a representative clinical dataset.

Serving starts at eight GPUs

The model card recommends eight H200 GPUs with tensor parallelism and expert parallelism both set to eight, or four GB300 accelerators. An FP8 checkpoint with 560 billion parameters requires roughly 560 GB for raw weights before runtime overhead, caches, temporary tensors, and long-context requests are included.

Deployment options
Option Details
Recommended hardware 8 H200 GPUs
Alternative hardware 4 GB300 accelerators
Primary runtime SGLang with tensor and expert parallelism
Additional runtime vLLM with Ling-3 parsers and MTP configuration
Published precision FP8
Listed quantization MXFP4

Reference SGLang launch

docker pull lmsysorg/sglang:dev-ling-3.1-flash

docker run --gpus all --network host --ipc=host --rm \
  lmsysorg/sglang:dev-ling-3.1-flash \
  python3 -m sglang.launch_server \
    --model-path inclusionAI/LingSante-3.1-flash \
    --tp 8 \
    --ep 8 \
    --speculative-algorithm NEXTN \
    --host 0.0.0.0 \
    --port 30000

The --tp 8 and --ep 8 settings use the same eight GPU workers. Tensor parallelism shards large tensor operations across them, while expert parallelism distributes mixture-of-experts computation. The NEXTN setting enables multi-token prediction speculative decoding, which drafts several tokens and verifies them to improve generation speed.

InclusionAI also documents optional Hopper-specific decoding flags that can improve single-batch decoding by roughly 10 percent. Actual gains depend on prompt length, output length, batching, and memory pressure. The vLLM path includes a ling3 tool-call parser, a reasoning parser, and MTP speculative decoding support.

A third-party Artificial Analysis listing includes the original FP8 release and an MXFP4 quantization. MXFP4 can reduce memory consumption enough to broaden the usable hardware configurations, with possible changes to accuracy and numerical behavior that require separate validation.

The example uses a mutable development image, host networking, and an unauthenticated service port. Production deployments should pin an image digest, restrict network access, add authentication, and scan the image and model dependencies before exposing an endpoint.

Research uses and clinical limits

The model card frames LingSante-3.1-flash as a research system and warns against independent diagnosis or treatment decisions. Its documented use cases concentrate on analysis, retrieval, extraction, and agent development with qualified human review:

  • Literature analysis and evidence synthesis across large document collections.
  • Structured extraction from clinical notes, reports, and research documents.
  • Retrieval-augmented applications that verify claims against tool outputs and cited evidence.
  • Medical agents that plan, call tools, inspect results, and revise their plans.
  • Research on professional behavior, multi-agent search, calibration, and cross-task integration.

Clinical deployments require controls beyond model weights and benchmark scores. Relevant safeguards include protected-health-information handling, encryption, access logging, retention policies, specialty-specific validation, human sign-off, abstention rules, citation checks, and monitoring for performance drift.

The MIT license permits commercial use, modification, and redistribution of the weights. Regulatory approval, patient-data compliance, and clinical fitness remain separate obligations governed by the deployment, jurisdiction, and intended use.

Scale needs outside validation

Large open-weight medical models remain uncommon, and the MIT license is unusually permissive for this category. Meditron-70B provides a useful older comparator, although its dense architecture differs substantially from LingSante’s sparse mixture of experts.

Parameter totals alone cannot rank the two systems. LingSante stores 560 billion parameters but activates about 25 billion for each forward pass, while a dense 70-billion-parameter model uses its full network. Hardware cost, throughput, memory use, context handling, and task accuracy therefore need direct measurement.

Ant’s training recipe tests whether a general model can acquire specialist medical behavior through mixed-domain training, reinforcement learning, and multi-teacher distillation while retaining broader reasoning and tool use. Independent evaluations will need to examine clinical accuracy, confidence calibration, evidence grounding, long-context reliability, quantization effects, throughput, and failure rates across specialties. Those results will determine where LingSante-3.1-flash is useful and where smaller or more specialized systems remain the better engineering choice.